Shed Wall Plans |
September 6th, 2020 |
house, shed |
The Facebook side of the discussion on the insulation post was very helpful, and got me thinking about putting closed cell foam panels directly against the concrete walls. Because it's both a vapor barrier and efficient insulation it reduces the risk of condensation happening between the concrete and the insulation.
I'm less sure about what comes next. Whatever I'm doing is not structural, and there are a lot of trade-offs. All of the options involve the layer of closed-cell foam directly against the concrete, but then they vary on how they're finished. Standard options:
Build a 2x3 wall, then drywall. This gives room to run the electrical, and wood to attach the drywall to. The wall would be attached to the subfloor below and roof joists above. Nothing needs to go through the foam to the concrete, and the wood framing makes later work easier.
Build a 2x4 wall. Same advantages as a 2 x 3 wall, but now there's enough space in the cavity that it could be insulated. I could either use this for a larger amount of insulation total, or reduce the thickness of the foam.(video example)
Furring strips. Run strips of wood horizontally along the wall, and attach them through the foam into the concrete. Then run a second set vertically, 16 inches on center, to attach the drywall to. There's room for electrical as long as you dig out a bit of the foam for the boxes. (video example).
Verticals inside: Instead of using furring strips, put vertical 2x3s from floor to ceiling, 16 inches on center. Attach them a the top and bottom (roof joists and subfloor). Attach the drywall to the wood. Run the electrical through the ceiling, and then down into the appropriate bay so you don't need to drill through any verticals. Essentially the same as the furring strip solution, but without needing to put fasteners through the foam into the concrete. This seems better than the furring strip approach?
Verticals outside: Attach the drywall to the foam with adhesive. Then instead of standard drywall joints, run 2x3s vertically 48 inches on center. Electrical in conduit, attached to the verticals. Mildly funny looking, doesn't feel quite as nice, maximizes space if you ignore the verticals.
foam | finish | overall | R-value | cost |
---|---|---|---|---|
1" | verticals outside | 1.5" | R-6.5 | $372 |
2" | verticals outside | 2.5" | R-13 | $580 |
1" | verticals inside | 3" | R-6.5 | $468 |
2" | verticals inside | 4" | R-13 | $676 |
3" | verticals inside | 5" | R-19.5 | $988 |
1" | 2x3 | 4" | R-6.5 | $536 |
2" | 2x3 | 5" | R-13 | $744 |
1" | 2x4 insulated | 5" | R-21.5 | $930 |
2" | 2x4 insulated | 6" | R-28 | $1138 |
This doesn't include the cost of the fasteners or adhesive, but seems about right. I'm leaning towards the approach of vertical 2x3s sixteen inches on center under the drywall with 2" foam, since it seems to offer a good balance of cost, insulation, and minimizing wasted space.
Comment via: facebook, lesswrong